No products in the basket.
| Part Number: | 756817-001 |
|---|---|
| Manufacturer: | HPE |
| Backup & Storage: | Storage Controller |
| Model: | HPE 3PAR STORESERV 7200C |
| Description: | Buy HPE 756817-001 3PAR 7200C Controller. Genuine part with fast worldwide shipping from Euroland IT Store UK. |
| Availability: | In Stock |
The HPE 756817-001 is a controller node for the 3PAR StoreServ 7200c. The c models were the converged refresh of the StoreServ 7000 range, adding more on-node cache and support for File Persona file services alongside block storage. Because the node design changed with that refresh, the 7200c has its own spare number and does not share a node with the original 7200.
Each 7200c runs two nodes as an active pair. Losing one leaves the array running on a single node with no controller redundancy, so a spare node is often kept on site by teams that still depend on these systems.
The 756817-001 is available in New and Refurbished condition, subject to stock. Select a condition on the product page to see the warranty that applies.
Although the names are close, the two arrays use different nodes. The original 7200 node is spare 683245-001 and the 7200 node pair carries 24GB of cache. HPE QuickSpecs give the 7200c node pair 40GiB of on-node cache, two six core 1.8GHz processors and two 3PAR Gen4 ASICs, with optional flash cache of up to 768GiB. The 7200c also supports File Persona, which the original 7200 does not.
For these reasons, buy the node that matches the model badge on your array. If the label on the failed node reads 756817-001, this is the correct spare.
Not every offline node needs a whole new node. Each 3PAR node boots from its own internal drive, and an HPE community thread on a 7200c shows a node going offline with a node IDE drive failure and a fatal boot error. In that case the owner replaced only the boot SSD, let the node run node rescue and the pair returned to normal. Contributors noted that a replacement boot drive should match the original in brand, type and size and should be blank.
Where the node itself has failed, the swap follows HPE’s warm swap process for the StoreServ 7000 family: the failed node is shut down with the enclosure powered, SFPs and any PCIe adapter are moved to the new node, and the new node rejoins through node rescue with its Ethernet cable connected. If you are unsure which part has failed, send us the error codes from the array and we will help.
New nodes are unused and suit customers who want a fresh spare for a production array. The warranty appears when New is selected.
Refurbished nodes are pre-owned HPE units and a sensible way to support a 7200c that is past its vendor support date. Choose Refurbished to view its warranty.
| Specification | Details |
|---|---|
| Part number | 756817-001 |
| Array | HPE 3PAR StoreServ 7200c |
| Nodes per array | 2 |
| Processors per node pair | 2 x six core 1.8GHz |
| ASICs per node pair | 2 x 3PAR Gen4 |
| On-node cache | 40GiB per node pair |
| Optional flash cache | Up to 768GiB |
| Onboard FC ports | 4 x 8Gb/s per node pair |
| PCIe slots | 1 per node |
| Adapter options | 4 port 8Gb FC, 2 port 16Gb FC, 2 port 10Gb iSCSI/FCoE, 2 port 10GbE or 4 port 1GbE for File Persona |
| Maximum host ports | 12 |
| Drive support | Up to 240 HDDs or 120 SSDs |
The node is not a match for the original 7200, the 7400 or 7400c, or the StoreServ 8000 series. Third party maintenance data from Park Place lists the 7200c end of service life as October 2022, so most replacements are now sourced from the spares market.
UK delivery is available and the options are shown at checkout. Send us the array serial number, the model and the failed node label details, and we will confirm the right replacement.
No. The 7200c has its own node, 756817-001, with more on-node cache and File Persona support. The original 7200 node is 683245-001.
Not always. A failed node boot drive can take a node offline, and replacing the drive and running node rescue may be enough. Check the array error codes first.
It runs node rescue when it powers up, loading the 3PAR OS from the running partner node over Ethernet, and then rejoins the cluster. A green LED blinking in step with the partner shows it has joined.
Park Place, a third party maintainer, lists the 7200c end of service life as October 2022. Many owners now rely on third party support and spares.
Select New or Refurbished to see the warranty for that option. UK delivery options appear at checkout.
You must be logged in to post a review.
Reviews
There are no reviews yet.