| Part Number: | E7807A |
|---|---|
| Manufacturer: | HPE |
| Servers Spare Parts: | Server Cable |
| Model: | DL580 G2, DL580 G3, P2000 G3, Synergy 12000 |
| Description: | Buy HPE E7807A 250V 10A Jumper Cord w/C14 to C15. Genuine part with fast worldwide shipping from Euroland IT Store UK. |
| Availability: | In Stock |
The HPE E7807A is a short power jumper cable with an IEC 60320 C14 plug at one end and a C15 connector at the other. HPE’s original datasheet describes it as a 200 to 250V, 10A jumper cable, 0.76 metres (29.9 inches) long, used to connect specific servers to a modular power distribution unit (PDU). The C15 end plugs into the back of the equipment and the C14 end plugs into the rack-mounted PDU.
The C15 connector looks similar to the common C13 but has a notch that allows it to fit higher-temperature C16 inlets as well as standard C14 inlets. That makes C14 to C15 jumpers useful for equipment whose power inlets run warmer. Our listing associates the E7807A with equipment including the ProLiant DL580 G2 and G3, the P2000 G3 storage array and the Synergy 12000 Frame.
Euroland IT Store offers the E7807A in New and Refurbished condition, subject to stock. Browse our HPE accessories for more power and rack parts.
Most IT equipment uses a C13 connector on the cord and a C14 inlet on the device. The C15 is a variant of the C13 with a groove opposite the earth contact, designed for equipment with C16 inlets that are rated for higher temperatures. A C15 connector fits both C14 and C16 inlets, while a C13 will only fit a C14. This makes the C15 a more versatile choice where equipment inlets may be either type.
In practice, C14 to C15 jumpers are used where the equipment end needs the higher temperature rating, or simply where the C15 style was specified by the equipment manufacturer.
At 0.76 metres, the E7807A is ideal for connecting equipment to a PDU mounted close by, such as a horizontal PDU in the same rack or a vertical PDU next to the device. Short cords reduce clutter at the rear of the rack, improve airflow and make it easier to see which cord feeds which power supply. In racks with many devices, swapping long cords for short jumpers can make a noticeable difference to cable management.
When planning rack power, start by listing every device and its power supplies, then decide which PDU each supply will connect to. Redundant power supplies should go to different PDUs, ideally fed from separate circuits or UPS units, so that one failure does not take a device offline. Choose cord lengths to suit the distance from each device to its PDU, with just enough slack for servicing. Using short jumpers like the E7807A where PDUs are close by keeps the rear of the rack tidy, making it easier to spot a disconnected cord and reducing the risk of accidental unplugging during maintenance work.
A New E7807A is unused and suits new rack installations. A Refurbished E7807A has been used before, checked and prepared for resale, offering an economical choice for replacements and spares. Always inspect power cords before use and replace any with damaged jackets, cracked connectors or bent pins.
The warranty and condition details for each option are shown on this page.
| Specification | Details |
|---|---|
| Manufacturer | HPE / Hewlett Packard Enterprise |
| Part Number | E7807A |
| Product Type | Power jumper cable |
| Connector 1 | IEC 60320 C14 (to PDU) |
| Connector 2 | IEC 60320 C15 (to equipment) |
| Voltage | 200 to 250V |
| Current Rating | 10A |
| Length | 0.76m (29.9 inches) |
| Listed Equipment | ProLiant DL580 G2/G3, P2000 G3, Synergy 12000 Frame (our listing) |
| Condition | New or Refurbished, subject to stock |
For standard C13 to C14 connections, see the HPE A0K04A 1.37m jumper cord or the HPE SG508A C13 to C14 cord. For high-power equipment needing 16A, the HPE AF574A C19 to C20 jumper cord is available. Our guide to power supply units explains server power in more detail.
Jumper cords connect equipment to a PDU or UPS, not to wall sockets. In UK data centres and server rooms, rack PDUs with C13 outlets accept the C14 end of this cable. Make sure the PDU and its supply circuit are rated for the total load of all connected equipment, and spread redundant power supplies across separate PDUs where possible.
Connect the C15 end to the equipment first, then plug the C14 end into the PDU. Route the cord so it cannot be pulled by sliding rails or caught by rack doors, and use any cord retention clips provided on the equipment or PDU. Check cords periodically for heat damage or wear.
Euroland IT Store supplies HPE power accessories across the UK. Orders over £100 plus VAT ship free to UK mainland addresses. See our shipping page for details.
It is a 0.76 metre HPE power jumper cable with C14 and C15 connectors, rated for 200 to 250V at 10A.
A C15 has an extra notch, allowing it to fit higher-temperature C16 inlets as well as standard C14 inlets. A C13 fits only C14 inlets.
According to HPE’s datasheet, the C14 end plugs into the PDU and the C15 end plugs into the equipment.
No. It is a jumper cord for connecting equipment to a rack PDU or UPS.
Yes. Orders over £100 plus VAT qualify for free shipping to UK mainland addresses.